Hanna CAL Check Standards for HI97105

Price: €92.90
Tax included
Hanna HI97105-11 CAL Check Standards is a certified cuvette set for validating and calibrating the optical performance of HI97105 and HI97115 Marine Master photometers. The sealed standards simulate known absorbance values at the instrument’s operating wavelengths, allowing meter performance to be checked without aquarium water or test reagents. The standards are NIST traceable and supplied in light-tight storage containers with a certificate of analysis listing the lot number, reference values and expiration date.
Product availability: Tilaustuote, norm. toimitusaika muutama viikko
Share
Available to order

HI97105-11 provides a convenient quality-control procedure for compatible Marine Master photometers. One cuvette zeros the instrument, while two absorbance standards verify performance at the relevant wavelengths.

The photometer guides the user through the CAL Check procedure on its display. If the measured values fall outside the accepted limits, the user can repeat the validation, perform the instructed calibration or arrange servicing where necessary.

Key features

  • CAL Check standard set for Marine Master photometers
  • Product code: HI97105-11
  • Compatible with Hanna HI97105
  • Compatible with Hanna HI97115
  • Validates optical meter performance
  • Supports user calibration
  • Contains one zero standard
  • Contains two absorbance standards
  • Sealed 13.5 ml cuvettes
  • Simulates defined absorbance values
  • NIST-traceable standards
  • Certificate of analysis included
  • Lot number and reference values documented
  • Expiration date provided
  • Light-tight storage containers
  • Not intended for testing aquarium-water parameters
  • Does not replace test-specific reagents

Technical information

  • Product: Hanna CAL Check Standards for HI97105
  • Product code: HI97105-11
  • Type: certified photometer validation and calibration standards
  • Compatibility: Hanna HI97105 and HI97115
  • Number of standard cuvettes: 3
  • Standard 1: HI97100-525
  • Standard 2: HI97100-610
  • Zero standard: HI97100 Zero
  • Cuvette volume: 13.5 ml
  • Traceability: NIST
  • Certificate of analysis: included
  • Storage: upright at room temperature in original light-tight containers
  • Refillable: no

Directions

  1. Check the expiration date.
  2. Allow the standards and photometer to reach the same room temperature.
  3. Open the instrument’s CAL Check function.
  4. Remove the requested standard from its light-tight container.
  5. Clean the outside with a lint-free cloth.
  6. Do not open or shake the standard cuvette.
  7. Insert the cuvette as instructed on the display.
  8. Complete the measurement sequence with all requested standards.
  9. Review the validation result.
  10. Perform the guided calibration if required.
  11. Repeat the check if an unexpected error occurs.
  12. Return every standard to its original storage container after use.

  • Brand
  • Reference
    HANNA-HI97105-11
Suojauskäytännöt
(muokkaa moduulissa Asiakkaan vakuuttaminen)
Toimituskäytäntö
Fast shipping
Palautuskäytäntö
Warranty quaranteed

Comments (0)

No customer reviews for the moment.

12 other products in the same category

Blue Life Fish Flux Rx
From
€38.90
Rated out of 5 stars based on review(s)
Blue Life Phosphate Rx
€51.90
Rated out of 5 stars based on review(s)

Related posts on the blog

Loading...
Back to top