Hanna CHECKER Plus pH tester
Price:
€110.90
Tax included
Hanna Checker Plus pH Tester HI98100 is a compact digital pH meter for aquariums, hydroponics, laboratory work and general water-quality monitoring. It measures from pH 0.00 to 14.00 with 0.01 pH resolution and offers automatic one- or two-point calibration. The replaceable HI1271 electrode extends the service life of the tester, while an on-screen stability indicator shows when the result is ready to record.
Checker Plus is designed for simple direct pH measurement. Its large LCD, single-button operation and automatic buffer recognition make routine testing straightforward.
The supplied HI1271 gel-filled electrode is approximately 103 mm long and tapers to an eight-millimetre sensing end. The narrow design fits test tubes, vials and other containers with small openings.
Key features
- Digital pocket pH tester
- Model: HI98100
- pH range: 0.00–14.00
- Resolution: 0.01 pH
- Accuracy: ±0.2 pH
- Automatic one- or two-point calibration
- Automatic buffer recognition
- Calibration tags on the display
- Stability indicator
- Low-battery indicator
- Selectable automatic shut-off
- Large LCD
- Single-button operation
- Replaceable HI1271 pH electrode
- Approximately 8 mm tapered sensing end
- Electrode length approximately 103 mm
- Suitable for aquariums and hydroponics
- Suitable for laboratory and field measurements
- Approximately 1,000 hours of battery life
- Compact and lightweight
Technical information
- Product: Hanna Checker Plus pH Tester
- Model: HI98100
- Measurement range: pH 0.00–14.00
- Resolution: 0.01 pH
- Accuracy: ±0.2 pH at 25 °C
- Calibration: automatic, one or two points
- Supported buffers: pH 4.01, 7.01 and 10.01
- Electrode: replaceable Hanna HI1271
- Electrode length: approximately 103 mm
- Sensing-end diameter: approximately 8 mm
- Automatic shut-off: 8 minutes, 60 minutes or disabled
- Battery: one CR2032
- Battery life: approximately 1,000 hours
- Dimensions excluding electrode: approximately 71 × 50 × 21 mm
- Weight: approximately 50 g
- Temperature measurement: no
- Automatic temperature compensation: no
Directions
- Calibrate the tester with fresh pH buffer solution.
- Use pH 7.01 for the first calibration point.
- Use pH 4.01 or 10.01 for the optional second point.
- Rinse the electrode with a small amount of the sample.
- Immerse the glass bulb and electrode junction in the water.
- Move the tester gently to release trapped air.
- Wait for the stability indicator to disappear.
- Record the result.
- Rinse the electrode after use.
- Store the electrode moist in proper electrode-storage solution.
- Never store the pH electrode in RO, distilled or deionised water.
(muokkaa moduulissa Asiakkaan vakuuttaminen)
Fast shipping
Warranty quaranteed
12 other products in the same category
JBL denitrol bacteria starter freshwater & saltwater 250ml
€26.90
Rated out of 5 stars based on
review(s)
Comments (0)
Your review appreciation cannot be sent
Report comment
Report sent
Your report cannot be sent