Salifert Strontium profi test
Price:
€28.90
Tax included
Salifert Strontium Profi Test is a multi-stage titration test for measuring strontium and calcium in marine and reef aquariums. It detects both ionically free and moderately complexed strontium with an approximate resolution of 5 mg/l. Natural seawater contains approximately 7–9 mg/l strontium, and the kit provides around 25 tests. It is intended for marine water only.
- Strontium and calcium test for marine aquariums
- Suitable for reef aquariums
- Detects ionically free strontium
- Detects moderately complexed strontium
- Approximate strontium resolution: 5 mg/l
- Natural-seawater reference: approximately 7–9 mg/l
- Useful for monitoring strontium supplementation
- Useful for checking newly mixed saltwater
- Suitable for SPS, LPS and mixed reefs
- Multi-stage titration procedure
- Approximately 25 tests
- No electronic meter or batteries required
- Marine water only
- UPC: 8714079130408
Technical information
- Product: Salifert Strontium Profi Test
- Alternative name: Strontium + Calcium Profi Test
- Test type: multi-stage titration test
- Parameters: strontium and calcium
- Strontium unit: mg/l or ppm
- Strontium resolution: approximately 5 mg/l
- Natural-seawater strontium: approximately 7–9 mg/l
- Number of tests: approximately 25
- Water type: marine water only
- Electronic meter required: no
Directions
Several versions of the test have been produced. Always use the instructions and conversion tables supplied with the individual kit.
The general procedure involves:
- Adding the specified marine-water sample to the test vial.
- Adding Sr-1 reagent and mixing.
- Adding a level measure of Sr-2 powder.
- Using the dedicated syringe to add Sr-3 reagent.
- Titrating to the first persistent blue endpoint.
- Adding Sr-4 with its separately designated syringe.
- Adding Sr-5 powder and observing the specified reaction time.
- Performing the final Sr-3 titration.
- Reading the syringe and determining calcium and strontium from the batch-specific tables.
- Cleaning the test vial thoroughly after use.
Do not interchange the reagent syringes. Sr-1 contains corrosive sodium hydroxide, so protective gloves and eye protection are recommended.
(muokkaa moduulissa Asiakkaan vakuuttaminen)
Fast shipping
Warranty quaranteed
12 other products in the same category
Hanna Checker pocket photometer for phosphate LR 000 to 250 mg/L
€86.90
Rated out of 5 stars based on
review(s)
Hanna Checker photometer for phosphate ULR 000 to 090 ppm
€86.90
Rated out of 5 stars based on
review(s)
Hanna General purpose cleaning solution bottle - 500ml
€39.90
Rated out of 5 stars based on
review(s)
Comments (0)
Your review appreciation cannot be sent
Report comment
Report sent
Your report cannot be sent