GHL ProfiLux 4 adapter for power cut monitoring
The GHL ProfiLux 4 Adapter for Power Cut Monitoring adds mains-failure detection to a compatible ProfiLux 4 system. The adapter monitors the normal electrical supply and sends a power-loss signal to the controller.
When a failure is detected, ProfiLux can automatically activate a selected maintenance program. This program determines which devices are stopped, which remain operating, and how compatible variable-speed equipment behaves during backup operation.
The adapter is not a battery, UPS, or backup power supply. Its function is to notify the controller that normal mains power has failed.
Energy-saving emergency operation
A power-cut program can be configured to:
- Switch off aquarium lighting
- Stop heating or cooling equipment
- Stop the protein skimmer
- Disable dosing pumps
- Suspend automatic top-off
- Suspend automatic water changes
- Reduce controllable pump output
- Keep essential circulation operating
- Activate backup aeration
- Trigger an alarm or notification
Switching off non-essential loads can significantly extend the operating time available from a UPS.
Compatibility
The adapter is designed for the LineMon input of compatible ProfiLux 4 controllers. It is not intended for sensor, PAB, switch-channel, or 1–10 V connections.
Key features
- Mains-failure detection for ProfiLux 4 systems
- Connects to the LineMon input
- Automatically activates a maintenance program
- Supports energy-saving emergency configurations
- Helps extend UPS operating time
- Allows essential circulation to be prioritized
- Supports controlled recovery after power returns
- Suitable for freshwater and marine systems
- Interchangeable Euro, UK, and USA plugs
- Product number PL-1607
Installation
- Connect ProfiLux and essential aquarium equipment to a UPS.
- Connect the monitoring adapter to a normal non-UPS outlet.
- Connect its signal cable to the ProfiLux LineMon input.
- Configure the power-cut maintenance program.
- Choose which devices remain active.
- Configure delayed restart where required.
- Test the system by disconnecting only the monitoring adapter.
- Confirm that ProfiLux remains active on UPS power.
- Confirm that the correct maintenance program starts.
- Confirm normal operation after mains power returns.